5. Testing
Keypad Printed* Meaning
Low Batt Rstr Low battery Restore Control unit low battery restored
Low Battery Low Battery Low battery on control unit
Test Call Man Trig Test Test call made
PA Knn Alarm K/P PA KEYPAD Panic alarm raised from keypad nn
PA Znn Alarm Panic Alarm ZONE Panic alarm raised from zone nn
PA Znn Rstr Panic Restore USER Panic alarm on zone nn restored
RF Jamming Jamming Start Radio jamming detected
RF Jamming Rstr Jamming End Radio jamming removed
RF Sup Fail Znn Supervision Fail ZONE Radio detector on zone nn failed
supervision
RF Sup Rstr Znn Super’ion Restore ZONE Radio detector on zone nn restored
to supervision
Set Fail Znn USER Exit Timeout ZONE System setting failed because of
fault on zone nn
Smk Det Alm Znn Smoke Det. Alarm Znn Smoke detector alarm on zone nn
Smk Det Res Znn Smoke Det. restore Znn Smoke detector on zone nn restored
Soak Fail Znn Test Zone Fail ZONE Soak fail test on zone nn caused
alarm
Sounder Tamp Rst Sounder Tamper Restore Tamper on sounder restored
Sounder Tamper Sounder Tamper Sounder tamper
System Rearmed Rearmed System rearmed
System Startup Startup Power applied to system
System Tamper Confirmed Zone 99
System Tamper Rst System Tamp Restore
Tamper Znn Sensor Tamper ZONE Zone nn cause tamper alarm
Tamper Znn Rstr Tamper Restore ZONE Tamper alarm on zone nn restored
Tech Znn Alarm TX ZONE Technical alarm on zone nn
Tech Znn Rstr TA Restore ZONE Technical alarm restored on zone nn
Tel Line Fault Tel Line Fault Telephone line fault detected
Tel Line Rstr Tel Line Restore Telephone line restored
Tcmd Low Bat Telecomm Low Battery Telecommand low battery
Telecmmd PA Telecmd Panic PA started from telecommand
Test Call Periodic Test The control unit made a test call
Unn Change Unn USER Changed USER User nn changed access code for
user nn
Unn Delete Unn USER Deleted USER User nn deleted access code for
user nn
Unn Off-Site USER Prog. Mode End Engineer exited programming mode
Unn On-Site USER Prog. Mode Engineer entered programming
mode
Bypass Supr. Znn Unn Supervision Bypass Znn Supervision on zone nn bypassed
Unn System Reset USER Reset User nn reset system
Unn System Set USER Armed LEVEL User nn set system
Unn System UnSet USER Disarm LEVEL User nn unset system
Unn System Unset USER Duress
Unn Time/Date USER Reset Time/Date User nn changed the time and date
Unn Znn Omit USER Omitted ZONE User nn omitted zone nn
Unn Znn Unomit Zone Unomit ZONE User nn un-omitted zone nn