4. Programming
496791 51
Local Sounder Delay on Entry (Command 26)
This Command controls the time at which local sounders operate in response
to an entry alarm.
Option 1 (default) introduces a delay to allow silent communications when an
entry alarm is triggered (required by some police forces). The option is only
valid under the following conditions:
Alarm abort off (Command 36).
Bell delay not zero (Command 41).
Dual Ply off (Command 86).
Alarm Confirm (Command 89) disabled.
If you enable option 1 the control unit starts the local sounders at the same
time as the external sounders if an intruder strays from the entry route, or the
entry time expires, and after any bell delay.
Option 0 causes the control unit to start the internal sounders immediately an
intruder strays from the entry route or the entry time expires.
Exit Fault External Sounders (Command 27)
When programmed with option 0 the system operates the internal sounders if
the user tries to exit while a zone is still violated (for example a door is not
shut). When programmed with option 1 the system operates the external
sounders as well as the internal sounders.
Status Display (Command 28)
Use option 1 of this Command if you do not wish to show keypad displays
permanently. The keypad displays “Level Set” for 180 seconds after the user
sets the system and then reverts back to the time and date display. Use this
option when installing a system in the U.K.
When set to option 0 the keypad displays “Level Set” the whole time that the
alarm system is set.
Use option 2 to make the keypad display revert to time and date 30 seconds
after any event. Note that if you use this option the and LEDs also
operate for only 30 seconds.
Entry Alarm Delay Time (Command 29)
Note: Disable Alarm Confirmation (Command 89) to gain access to this Command.
This Command determines what the system will do if a user strays from an
entry route zone during entry. (This Command is available to provide compli-
ance with EN 50131-1.)
Use option 0 to make the system give an alarm immediately if the user strays
from an entry route zone during entry.
Commenti su questo manuale