3. Installation
Initial Start Up
Before applying power to the control unit, ensure that:
• All remote keypads and expanders have been addressed and con-
nected.
• All external and internal sounder are connected.
• All wired zone circuits are connected.
• All wireless zones have been learned to their expanders.
Then:
1. Connect the battery to the control unit PCB.
2. Briefly short the kick start pins together (they are located above battery
connector, see Figure 3).
The green power LED on the keypad flashes and the internal sounder
may sound. Ignore any display at this stage.
3. Key-in the factory default user access code: 1234.
The internal sounder stops. Ignore any display at this stage.
4. Fit the case lid before applying mains power (this also defeats the
tamper switch).
5. Apply mains power.
The power LED on the keypad glows steadily.
6. Key-in 0 followed by the factory default engineer access code: 7890.
(You do not have to remove the control unit lid.)
The display shows:
7. Either: Press 1 to create a partitioned system
Or 0 to create a single system (see below).
The display shows:
You are now in programming mode.
Carry on to Chapter 4 in order to program the system.
Partitioned System Or Single System?
The 9851 can work as either a single system or partitioned system. When
working as a single system the 9851 has one full set and three part set levels
of security. All keypads, zones and output devices operate for the whole
system.
If you chose a partitioned system you can divide the 9851 into, effectively,
four smaller alarm systems.