4. Programming
496791 69
Alternate (2) Reports to one of two programmed telephone numbers (see
Commands 115 and 116).
Operation: The system dials the first telephone number and
attempts to connect to the ARC. If it fails, it will then close
down and dial the second telephone number and attempt to
connect to the ARC. If received and acknowledged on this
attempt, the system will close down and the alarm transmis-
sion will be complete. If the system fails to connect to the
second telephone number, it will close down again and re-
attempt to connect to the first telephone number. The
system will continue to shuttle between the two numbers up
to 15 times.
Dual (3) Reports to two different receiver numbers (see Com-
mands 115 and 116).
Operation: The communicator dials the first telephone
number and attempts to connect to the first ARC. If
received and acknowledged, the communicator dials the
second number and attempts to transmit to the second
ARC. If received and acknowledged by the second
number, the communicator will close down and the alarm
transmission will be complete. If calls to the first number
fail, then the communicator attempts to call the second
number. If the communicator fails to connect to the
second telephone number, it will close down again and re-
attempt to connect to the first telephone number. The
communicator will continue to shuttle between the two
numbers, calling each number up to 15 times, until it has
successfully called both numbers.
Note: Dual reporting does not work with SIA or CID reporting formats.
Reporting Type (Command 103)
The system offers four message formats:
Option 0 Scancom Fast
Option 1 Contact ID
Option 2 Scancom SIA Level I
Option 3 Scancom SIA Level II (does not send time and date).
Option 4 Scancom SIA Level 3
Option 5 Extended Scancom SIA Level 3