496791 19
3. Installation
Zone 1
Zone 3
Zone 4
Zone 2
2K2 EOL
Alarm contacts
2K2 EOL
2K2 EOL
Alarm contacts
Global anti Tamper Loop
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Zone 5
Zone 6
Zone 7
Zone 8
Figure 13. EOL Connections
Connecting Expanders
Figure 14. shows how to wire a 9954 Hard Wired Expander or 9955 Radio
Expander to the control unit.
0V 12V CLK DATA
To other keypads
12V
0V
DATA
CLK
Expander
Control Unit
Figure 14. Connecting a 9954
When fitting a 9954 Expander make sure you place the jumper link on the
expander in the correct position to select either four-wire CC, or two-wire FSL
or EOL.
Note: Make sure that the control unit and the expander use the same wiring method
for zones. If you select a different wiring method for zones on the expander
then the control unit may not report tampers correctly.
Commenti su questo manuale