496791 21
3. Installation
OP3
TR
ST
LS
TR
ST
LS
+ve 12V Aux
Shock Sensor Reset
Use Command 83 4
VIPER
+ve
0V
OP3
TR
ST
LS
TR
ST
LS
+ve 12V Aux
+ve 12V Aux
French Siren Test
Use Command 83 X1
(for use in France only)
SIREN
+ve
0V
OP3
+ve 12V Aux
Bell Follow Buzzer/Relay
Use Command 83 0
Relay energises/buzzer sounds
when bell activates.
BUZZER/RELAY
OP3
PIR Set Latch/Walk Test
For:
Set Latch use Command 83 3
Walk Test use Command 83 5
PIR
Figure 17. Wiring Examples for Programmable Output OP3
Wiring Keyswitches
Figure 18 shows the connections for a 9928 Keyswitch Interface.
Note: You can fit only one keyswitch interface per system
M/C
M/C
M/C
0V
12V
CLK
DATA
ET
PA
SET
RDY
9928
COM
KS2
KS1
Set A
Off
Set B
Set A
Set B
TAMP
Momentary
Continuous
To keypad bus
on control unit.
Figure 18. Connecting a 9928 Keyswitch Interface