4. Programming
64 496791
For a partitioned system:
Option 0 Keypad sounders only.
Option 1 Local alarm (internal and external sounder only).
Option 2 Full alarm (communication and internal/external sounders).
Level D Entry Time (Command 78)
This Command sets the entry time for part set D or Partition D. See “Pro-
gramming Commands” for options.
Level D Exit Time (Command 79)
This Command sets the exit time for part set D or Partition D. See “Program-
ming Commands” for options.
Note: In a single system, you cannot program entry/exit and entry route zones assigned
to part set D to change functions when the user sets part set D. Cooper Security
recommend that you use part set D for simple applications only.
Output Programming (Commands 81, 82, 83 and 84)
The system has four programmable outputs. OPs 1 and 2 are zero voltage
relay outputs, while OPs 3 and 4 are transistorised, high current outputs.
Command 81 programs output 1, Command 82 programs output 2, Com-
mand 83 programs output 3 and comand 84 programs output 4. All three
Commands take a single following digit that selects the function.
Note: OPs 3 and 4 are a "pull down” type that provide negative applied control
signals. The outputs are +12V when inactive, and 0V when active.
Output Type
Bell (Key in 00) The control unit operates this output during
an alarm. Use Command 41 to control bell delay and 42
to control bell duration.
In a partitioned system the control unit operates this
output when any any partition is in alarm.
If you enable Alarm Confirmation (Command 89) then
use Command 162 to select whether the control unit
activates the bell on a first or a confirmed alarm.
EE Follow (Key in 01) This output is active when the entry or exit
time starts and deactivates at the end of the entry/exit
time, or if the entry/exit time is terminated. The output
can be used for a separate entry/exit buzzer. Note that
the output does not give a tone during part set if the exit
mode is silent set or instant set.
Armed lamp (Key in 02) The output is active continuously while the
system is full or part set.