4. Programming
496791 71
Dynamic Test (Command 108)
In dynamic testing the system makes a test call 24 hours after the last
communication. Select option 0 to disable dynamic test calls. Select option 1
to enable dynamic test calls.
Note: Cooper Security Ltd recommend that you chose either Static Test Call (105) or
Dynamic Test Call, but not both at the same time.
Three Way Call - UK only (Command 109)
To use Three Way Call you must make sure that the BT Network Services
Option of ‘Three Way Calling’ is available on the telephone line to which the
communicator is connected.
Three way off (0) Disabled
Three way on (1) Three Way Call.
Operation: If the control unit triggers the communicator
and the communicator detects Off Hook or Incoming
Ringing, the communicator then sends a 80 ms trigger
(which represents the “R” or Recall button on a tel-
ephone) which is detected by the exchange as a request
for a new clean line. With the new line available, the
communicator then attempts to connect to the pre pro-
grammed receiver number.
Engineer Download (Command 110)
The control unit can be programmed from a PC using <Downloader> soft-
ware. You can connect the PC to the control unit either over the telephone
network, or locally using a cable.
Use Command 110 to manually connect the control unit to the PC.
Local (0) To connect the control unit to a PC (for example a laptop)
using a local cable key in 110 0 .
Remote (1) To automatically answer calls coming from a remote PC
over the telephone network key in 110 1 . You will
also need to use Commands 112, 113. (Note that Secure
callback does not work with this option.)
Note: The control unit will leave Command 110 if <Downloader> does not make a
call within 30 minutes.
While the control unit is connected to the PC you can upload its programming
configuration into <Downloader> in order to inspect it. Using <Downloader>
you can change the configuration and then transmit the new configuration
back to the control unit. If you do not wish to change the configuration you
can simply monitor the state of the control unit and zones from the PC.