1. Introduction
other detectors or remote setting switches apart from the ones it has learned.
See the separate "RFX Installation and Programming" manual for more
details.
Configurations
Since the control unit can use a variety of wiring types for detectors, and you
can also attach either hard-wired or wire-free expanders, the table below
shows the configurations possible:
Wiring Type Control Unit Zones Expansion Zones
CCL 8 32 wired OR 32 radio
FSL 8 32 wired OR 32 radio
FSL 16 24 wired OR 24 radio
EOL 8 32 wired OR 32 radio
Partioned or Single System
During installation the engineer can organise security Levels A to D as either
a partitioned system or as a single system.
In a partitioned system the users can set or unset each Level independantly
of, or at the same time as, any of the others. The Installer can allocate each
Level its own set of zones and keypads, and an independant sounder output.
User 01 can allocate any user to any of the Levels.
In a single system the users can set only one Level at a time. Level A sets
the whole system. Levels B, C and D set parts of the system. The Installer
allocates zones to Levels, but all keypads operate the entire system, and
there is only one sounder output for the whole system. All users belong to the
whole system.
User Control
The control unit provides 16 independent user access codes and a separate
Duress code. The user can change these codes at any time, but cannot
program the system with these codes. You can select either four-digit or six-
digit access codes during installation.