4. Programming
68 496791
Commands 90 - 97, See “5.Testing”
Load Full Defaults (Command 98)
Use this Command to load default values for all Commands.
1. Enter programming mode (if you are not already there).
2. Key in 98 at the keypad.
The display shows:
3. Press 1 at the keypad.
The display shows (for example):
4. Either: Press 1 to create a partitioned system
Or 0 to create a single system.
The display shows (for example):
5. Press .
The keypad gives a double confirmation tone and the system loads the
factory default Command values, erasing all previously programmed
values.
Notes:The log is protected and cannot be erased by the Installer.
Leave Programming Mode (Command 99)
To leave programming mode:
1. Key in 99 at the keypad.
The display shows:
2. Press .
The display shows:
and after a few seconds the contol unit
resets itself and returns to user mode.
If any 24 hour, Fire, PA or Technical zones are active when you try to leave
programming mode then the keypad gives an error tone and displays all the faults.
Clear the faults shown on the display and press . Repeat steps 1 and 2 and
the control unit should leave programming mode.
Call Mode (Command 101)
You may select one of the following call modes:
Disabled (0) The control unit does not use any communications.
Single (1) Reports to a single telephone number (see Command
115) with a single account number (see Command 117).
Operation: The system dials the number and attempts to
connect with the ARC. If it fails, it closes down and then
re-attempts to connect up to a maximum of 15 times.