4. Programming
496791 83
Partition A B C D
Exit Mode C39 C62 C72 C76
Alarm Reponse C47 C63 C73 C77
Entry Time C43 C64 C74 C78
Exit Time C44 C65 C75 C79
4. Use Commands 81 to 84 to assign bell outputs to each Partition as
required.
Option 5 assigns an output to Partition A
Option 6 assigns an output to Partition B
Option 7 assigns an output to Partition C
Option 8 assigns an output to Partition D
5. Make sure that the master user understands how to assign individual
user codes to each Partition.
Command Changes
When using a 9851 as a partitioned system then some of the programming
Commands offer new options. Other programming Commands can no longer
be used. The table below summarises all the programming differences
between Partitioned systems and single systems.
Command Partition System Single System
01-40 Zone Programming X5 to X8=Partitions X5 to X8=Part Sets
28 Status Display "Partn. Set." "Level Set"
32 Keypads and Partns. Link Kpd to Partition Not available
39 Partition A Exit Mode Opts 3 and 4 avail Opts 3 and 4 not avail
43 Partition A Entry Time No change
44 Partition A Exit Time No change
45 Entry/Exit Tone Volume Not available Available
47 Partition A Alarm Response Available Not Available
60 Level B Final Exit Not available Available
61 Level B Entry Route Not available Available
62 Partition B Exit Mode Options 2-4 change Options 2-4 change
63 Partition B Alarm Response Options 1-3 change Options 1-3 change
64 Partition B Entry Time No change
65 Partition B Exit Time No change
70 Level C Final Exit Not available Available
71 Level C Entry Route Not available Available