4. Programming
496791 37
To change: Key-in: Notes Default
Level C Alarm Response 73 n
For a single system n is one of the following:
0 Keypad sounder only
1 Internal sounder and keypad sounders Y
2 Local (all sounders, no comms)
3 Full alarm (all sounders and comms)
For a partitioned system n is one of:
0 Keypad sounder only
1 Local alarm
2 Full alarm Y
Level C Entry Time 74 1 10 seconds
2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Level C Exit Time 75 1 10 Seconds
2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Level D Exit Mode 76 n
For a single system n is one of the following:
0 Timed plus low tone (default)
1 Instant set
2 Silent set (kpd beeps at end of setting period)
3 Exit mode same as Level A
For a partitioned system n is one of:
0 Timed full tone Set (default) 3 Instant set
1 Terminated 4 Silent (kpd beeps at end of setting period)
2 Final door 5 Lock Set
Level D Alarm Response 77 n
For a single system n is one of the following:
0 Keypad sounder only
1 Internal sounder and keypad sounders Y
2 Local (all sounders, no comms)
3 Full alarm (all sounders and comms)
For a partitioned system n is one of:
0 Keypad sounder only
1 Local alarm
2 Full alarm Y