4. Programming
50 496791
Option 1 Eight End of Line resistor (EOL) zones on control unit, plus up to
32 zones on expanders.
Option 2 16 Fully Supervised Loop (FSL) zones on control unit, plus up to
24 on expanders.
Option 3 Eight FSL zones on control unit plus up to 32 zones on expand-
ers.
See Chapter 3 for wiring details.
Loudspeaker Chime (Command 22)
In a single system a user may find that the chime tone from the keypads is
not loud enough. If so, then use Command 22 option 1 to make the internal
sounder also give the chime tone. To alter the volume of the tone from the
internal sounder enter a digit in the range 1 to 9. 1 is quietest, 9 is loudest.
The internal sounder demonstrates the volume of the tone when you enter
the digit. Note that this Command is not available in a partitioned system.
RedCare Reset (Command 23)
Option 1 enables RedCare Reset, which is designed to operate with the plug-
by communicator, or remote PC reset.
Note: You must set System Reset to Engineer (Command 33 option 1) to ensure
RedCare Reset works correctly.
After an alarm the user keys in their access code to silence the alarm, but
cannot reset the system. The first to alarm display and Service LEDs remain
visible. The user contacts the ARC, who verifies the user's identity. The ARC
sends a signal back to the control unit. The Service LED goes dark and the
end user can now reset the system with any valid access code, providing that
there are no faults.
Use option 0 (the default) to disable the function.
Show Control Unit Account Name (Command 24)
An ARC can use Downloader to program an account name into the control
unit. While the control unit is in programming mode you can display the
account name from the keypad. To do this key in 24 . Press to return to
programming mode.
Continuous Sounder (Command 25)
Option 0 of this Command makes the internal sounder follow the external bell
delay and duration times. Option 1 makes the internal sounder continue after
the external bell times out.