20 496791
3. Installation
FSL
EOL
Four-wire CC
Two-wire FSL
Two-wire EOL
Figure 15. Jumper Positions to Select Connection Types
Once you have connected a 9954 expander refer to the instructions supplied
in order to connect detectors.
Once you have connected a 9955 expander then refer to the instructions
supplied in order to "learn" radio detectors to the expander.
Expander Addressing
If you fit 9955 or 9954 expanders then you must allocate each expander to a
specific range of zone numbers. Select the zone numbers by fitting a jumper
link to one pair of the set of pins marked "Address", as shown in Figure 16.
2
3
4
2
3
4
2
3
4
Zones 9 to 16
Zones 17 to 24
Zones 25 to 32
Zones 33 to 40.
2
3
4
Figure 16. Link Positions to set Expander Addresses
Notes:
1. Fit a jumper in either position 2, 3 or 4 if the control panel is providing zones
1 to 16.
2. Do not allocate two expanders to the same zone number range.
Using Programmable Outputs
OP1 and 2 are voltage free relay contacts. Use programming command 81
for OP1 and command 82 for OP2.
OP3 and OP4 are "pull down type" outputs that provides negative applied
control signals. Use command 83 for OP3 and 84 for OP4 (see "4. Program-
ming"). The system adjusts the output polarity when you select the output
type. Figure 17 shows some example applications for OP3 and OP4.
Commenti su questo manuale