4. Programming
496791 55
keypad ET terminals. In a single system, do not attempt to fit two
lockswitches.
To set the system the user first enters their access code at a
keypad or operates a keyswitch. The control unit starts the exit
tone. Note that the exit time is infinite in this option. The user then
operates the final exit zone and turns the key in the lock switch to
“locked”. The system sets seven seconds after the lock switch
contacts open.
To unset the system the user turns the lock switch to “unlocked”
(closing the lock switch contacts). The keypads start a continuous
tone. At this point the user can lock the lockswitch again without
causing any alarm. When the user opens the final exit zone the
control unit starts the entry timer. The user completes entry by
unsetting the system in the normal way. Note that when the user
unlocks the lockswitch the control unit disables Alarm Confirma-
tion. The control unit enables Alarm Confirmation again if the user
locks the lockswitch without starting the entry timer.
If an intruder opens the final exit door without first unlocking the
lockswitch then the control unit immediately starts an unconfirmed
alarm. If the intruder goes on to violate another zone and you
have enabled Alarm Confirmation then the control unit sends a
confirmed alarm.
Note that the keypads give a double beep confirmation tone at the end of all
setting modes.
If you select Timed (options 0), Terminate (option 1), or Final Door (option 2)
exit modes the system allows a seven second settling time after pressing an
exit terminate button or closing a final door.
System Auto Re-Arm (Command 40)
This Command lets you program the number of times that the system will re-
arm when the bell delay expires. The system re-arms all closed zones. Select
option 0 to make the system never re-arm (the system will go into alarm once
only). Select options 1 to 4 to make the system re-arm once, twice, three
times or always.
Use this Command in conjunction with Command 35 - First Circuit Response.
If the system has rearmed, then when a user enters the system through the
entry route the control unit will give an audible internal alarm in place of the
normal entry tone.
Bell Delay (Command 41)
When the system is set and (for example) an intruder violates a zone, then
the system waits for the programmed Bell Delay before operating the exter-