Pagina 1 - Manager's

M-Series Manager's Manual

Pagina 2

8 Option 1-2: Omitting Zones Sometimes you may need to omit zones when you set your wards, e.g. if a zone is to remain occupied while the rest of t

Pagina 3 - Contents

9 Option 1-3: Shunting 24hr Zones This option enables you to shunt (disable) all 24 Hour zones in selected wards that have been set up as shunta

Pagina 4 - Introduction

10 Option 1-4: Changing your User Code This option enables you to change your own user code. To make changes for other users, refer to page 21. Use

Pagina 5 - Accessing the User Menus

11 Option 1-5: Enabling Chimes This option enables you to select which of your wards (if any) use the chime feature. In a ward with this feature

Pagina 6 - Option 1-1: Testing

12 Option 1-6: Setting the Speaker Volume This option enables you to adjust the volume level of the extension loudspeaker connected to the control

Pagina 7

13 Option 1-7: Customising Text This option enables you to edit the following text strings: Banner Text This message is shown on the top line of

Pagina 8

14 Option 1-8: Setting Up Silent Set Wards This option enables you to select which of your wards (if any) set silently, without emitting an exit to

Pagina 9

15 Option 1-9: Configuring Engineer Access This option enables you to define a period during which an engineer can log into the alarm system. On

Pagina 10

16 Option 1-0: Accessing the Set/Unset Menu The set/unset menu is displayed whenever you enter your user code or present your proximity tag. This o

Pagina 11

17 Options in User Menu 2 Option 2-1: Viewing Zones This option enables you to view the status of each zone, which may be: HealthyThe normal st

Pagina 12 -

© Cooper Security Limited 2007 Every effort has been made to ensure that the contents of this book are correct. However, neither the authors nor Coop

Pagina 13 - : Enabling Chimes

18 Option 2-2: Setting the Time and Date This option enables you to set the system time and date. Z The system automatically advances/retards the

Pagina 14 - : Setting the Speaker Volume

19 Option 2-3: Setting Up Shunt Groups Shunt groups provide a simple way to isolate zones until further notice. Each shunt group can contain up

Pagina 15 - : Customising Text

20 You can view any of the eight possible zones assigned to the group by using | or ¬, or pressing the hot key (1 to 8). If you want to delete

Pagina 16 - Ward > **

21 Option 2-4: Setting Up User Codes This option allows you to define users to operate the alarm system. When setting up a user, you need to spec

Pagina 17 - Engineer Access

22 About the User Types The following user types are available. (Press the key shown next to the type name to select a type directly.) Manager 1 User

Pagina 18

23 Easy Set 5When unsetting, all associated wards are unset and the keypad displays no options. The system sets with no options, providing auto-se

Pagina 19 - Option 2-1: Viewing Zones

24 Allow setting in Engineer option 1-9-1-24 must be set to YES. Access 9Users of this type have no access to user menus and cannot set or unset the

Pagina 20

25 Option 2-4-1: Configuring the User Codes This option enables you to set up or modify users. For each user, you specify information such as the

Pagina 21

26 User 05 wards Ward > 1*... 6. Use the numeric keys to select the wards you want the user to have access to, then press [. Any ward numbers

Pagina 22 - Zone >

27 Option 2-4-2: Defining User Names This option enables you to specify a name for each user. When viewing the event log (page 37), pressing r tog

Pagina 23

1 Contents Preface...2 Introduction...

Pagina 24 - Prox Tag User 4

28 Menu 1 Options:- > 0123456789 4. Select the User Menu 1 options to which the user should have access, then press [. Pressing 0 to 9 selects (o

Pagina 25 - Duress Code 8

29 Option 2-4-4: Programming Telecommands Use this option to allocate telecommand or PA buttons to individual wards. Cooper Security Limited recom

Pagina 26 - Not in use

30 allocated ward) only when in range of a specific MRNode receiver1. OR: Unused: The control unit will ignore any telecommand programmed as Unused,

Pagina 27

31 Telecmd 1 ^elecommand Name 9. Press [ to select this option. Use the text editing keys (page 48) to edit the telecommand name, then press [ to

Pagina 28

32 Option 2-5: Setting Up Chime Zones This option enables you to select which zones generate a chime if activated when unset, or to switch chimes o

Pagina 29

33 Option 2-6: Using Communications Option 2-6-1: Starting a Call Back You can use this option to initiate a connection over the telephone line to

Pagina 30 - Menu 2 Options:

34 Option 2-6-2: Editing the Call-Back Numbers This option allows you to define or edit up to four telephone numbers for communication with a PC runn

Pagina 31

35 Option 2-7: Assigning Zones to Wards The assignment of zones to wards is usually carried out by your alarm company. Change these assignments

Pagina 32

36 Option 2-8: Setting Up Ward Groups This option enables you to allocate wards to groups, which you can then set or unset with a single operation

Pagina 33 - ^elecommand Name

37 Option 2-9: Using the Log Option 2-9-1: Viewing the Log This option enables you view the contents of the system log. The log contains the date

Pagina 34

2 Preface Introduction About your Alarm System Your intruder alarm system provides comprehensive and flexible protection for domestic or commercial

Pagina 35

38 Option 2-9-2: Printing the Log If a printer is connected to the control unit, you can print some or all of the events recorded in the log. User 2

Pagina 36

39 Option 2-9-3: Viewing the Access Log You can use this option to view the content of the access log, which stores every use of a user code of ty

Pagina 37

40 Option 2-0: Setting Up Timers Option 2-0-1: Setting Up Time SwitchesThis option enables you to define up to three time switches, which can be used

Pagina 38

41 Z You can manually override a time switch by pressing 0, then pressing r to toggle its current status. Time Switch 1 On (1) >00:00 5.

Pagina 39 - : Using the Log

42 Option 2-0-2: Setting Up Auto-Set Timers Use this option to make the control unit set or unset selected wards at specified times. The control unit

Pagina 40

43 Auto Set 1 3. Use | or ¬, or press a hot key (1 to 3) to select the auto-set timer to edit, then press [. (The display shows the timer n

Pagina 41

44 1 Operates On :- > ... When editing the days press 1 to 7 to toggle days on/off, then press [. On the days screen the event numb

Pagina 42 - : Setting Up Timers

45 Option 2-0-3: Setting Up Code-Locks Timers Use this option to lock out one or more users at specified times. The control unit has three code-lo

Pagina 43 - >

46 4. To select the on/off time or days of operation to edit, EITHER Use | or ¬ then press [. OR Press a hot key (1 to 9) then press [. The

Pagina 44 - Auto-Sets

47 You can now: • Continue with step 6 to specify other users as necessary. • Press ] and continue from step 4. • Press ] twice to exit.

Pagina 45

3 Accessing the User Menus To access the user menus: BANNER TEXT 17:30 Sun 01 JAN 1. Enter your user code or present your proximity tag. 0=Set

Pagina 46 - Auto Set 1

48 Text Keys The following table shows how to obtain characters when entering text at the keypad. For example, press 2 twice to obtain the "B&

Pagina 47

49 Zone Numbering Each zone has a unique 4-digit number. The meaning of the number is as follows: For all zones except those using iD Plus biscu

Pagina 48

50 Radio Systems You security system may be fitted with a radio receiver (called an MRNode) that ‘listens’ for signals from wire-free detectors and

Pagina 49 - • Press

51 any programming of PA buttons, but you can give them a name and allocate them to individual wards. Telecommand Buttons The 722r, 723r, 727r and

Pagina 50 - Text Keys

52 Log Events Event Description --- NO EVENT --- Not used ### LECS or REMS The number of LEC or keypads logged on to system after a re-learn ###

Pagina 51 - Zone Numbering

53 Event Description BEAM PAIR #### First activation of a beam pair zone number #### BELL BOX TAMPER Not used BELL FUSE Bell fuse tripped BEL

Pagina 52 - Telecommands and PAs

54 Event Description MASK TMP S #### Masking zone #### masked when set MASK TMP U #### Masking zone #### masked when unset MENU TIMEOUT #### Sy

Pagina 53

55 Event Description SHNT #### REINST Shunted zone #### reinstated SHUNT CODE #### User #### of type "Shunt" entered passcode to isol

Pagina 54 - Log Events

56 User Codes and the Log When displaying or printing the log, the control unit shows users as a number (shown in the table of log events as “####”).

Pagina 55 - Event Description

57 System Records General System Details Wards 1 2 3 4 5 6 7 8 Entry Time Exit Time Setting Mode

Pagina 56

4 Options in User Menu 1 Option 1-1: Testing Option 1-1-1: Testing the Bell This option enables you to test the internal sounder, strobe, external s

Pagina 57

58 Ward Groups Group Name Wards Group Name Wards 1 6 2 7 3 8 4 9 5 0 Shunt Groups Group Zone 1 Zone 2 Zone 3 Zone 4 Zone

Pagina 58 - User Codes and the Log

59 Auto-Set Timer 1 Timer Set at Unset at Mon Tue Wed Thu Fri Sat Sun 1 2 3 Set Wards: Auto-Set Timer

Pagina 59 - General System Details

60 User Details No. Name Type Wards Auto-set Auto-Unset 1 Manager

Pagina 60

61 Zone Details Zone No. Location Chime Y/N Wards

Pagina 61

62 Service Record Date Engineer Action

Pagina 62 - User Details

63 Installer Information Installation Engineer: Installation Company: Address: Telephone Number: Reset Message: Alarm Receiving Cen

Pagina 63 - Zone Details

64 Quick Reference BANNER TEXT 17:30 Sun 01 JAN 1. At the keypad, enter your user code or present your proximity tag. 0=Set Selection [Ent]=User Le

Pagina 66 - Quick Reference

5 Option 1-1-2: Performing a Walk Test This option enables you to check that zones are operating correctly. You can test only those wards that you

Pagina 67

6 Option 1-1-3: Telecommand Batteries This option enables you to check if any telecommands have reported a low battery. User 1 Menu 1 Test Menu 1. P

Pagina 68 - 11751729

7 Option 1-1-4: Telecommand Test This option enables you to test a telecommand, or identify an unknown telecommand. User 1 Menu 1 Test Menu 1. Pre

Commenti su questo manuale