23
Easy Set 5
When unsetting, all associated wards are
unset and the keypad displays no options.
The system sets with no options, providing
auto-set wards are set up. The user can
set/unset from any keypad.
Z
You must set up wards assigned to an
Easy Set user as auto-set and auto-
unset, see page 26 onwards.
Reset Only 6
Users of this type have access to User Menu
1, options 1, 2, 3, 4, 5, 8 and 9. They can
reset 24-hour alarms from any keypad.
Panic Code
7
Users of this type have no access to user
menus and cannot set or unset the system.
Entering a user code of this type generates
a Panic Alarm and activates a full alarm
(causing internal and external sounders and
strobe lights to operate).
Z
To set up a Panic code, Duress Allow in
Engineer option 1-9-1-24 must be set to
YES.
Duress Code 8
Users of this type have the same abilities as
a standard global user but, when the user
code is entered, a silent alarm is
generated
1
, which could be sent to an
alarm receiving centre. This enables the
user to appear to operate the alarm system
normally if being coerced.
Z
To set up a Duress code, the Duress
1
Outputs of type "Duress Alarm" are activated if the system is being set. Outputs of type "Duress Alarm" or "Panic
Alarm" are activated if the system is being unset.
Commenti su questo manuale