HARDWIRED CONTROL
PANEL
INSTALLATION AND
PROGRAMMING GUIDE
Scantronic
Vedere la pagina 0
1 2 3 4 5 6 ... 70 71

Sommario

Pagina 1 - PROGRAMMING GUIDE

HARDWIRED CONTROLPANELINSTALLATION ANDPROGRAMMING GUIDEScantronic

Pagina 2

4 4964781. IntroductionOperator Controls and Displays - 9925Figure 3. 9925 Arming Station.The 9925 arming station is intended for use solely in settin

Pagina 3 - Contents

496478 51. IntroductionSystem FeaturesDetectorsThe control unit provides connections for up to eight separate detectorzones. Each zone can be connecte

Pagina 4

6 4964781. IntroductionUser ControlThe control unit provides eight independent user access codes and a sepa-rate Duress code. The user can change thes

Pagina 5 - 496478 iii

496478 72. Technical Description2. Technical DescriptionSpecificationOperating temperature = -10° to +55°CHumidity = 96% RHDimensions = 243mm W, 234mm

Pagina 6

8 4964782. Technical DescriptionControl Unit PCB and CaseFigure 4 shows the layout of the control unit PCB.Telephone line for built-in communicatorBat

Pagina 7 - 1. INTRODUCTION

496478 92. Technical Description9755 ExpanderThe 9755 Expander provides connectors for eight four-wire CC loop zones.Figure 5 shows the layout of the

Pagina 8 - Figure 1. 9750 System Layout

10 4964782. Technical DescriptionCompatible Equipment715rEUR-00 Radio PIR.719rEUR-00 Radio Smoke Detector.725rEUR-00 Radio Remote Setting Device.726rE

Pagina 9 - 496478 3

496478 113. Installation3. INSTALLATIONNote: The following instructions assume that you have already run the necessarycabling.Caution: Always remove m

Pagina 10 - 4 496478

12 4964783. Installation6). Make sure that the bottom left corner of the PCB is seated on itssupport pillar.Fitting a 9930 LCD KeypadThe backplate of

Pagina 11 - 9955 Radio Expander

496478 133. Installation6. Mount the front of the keypad (containing the keypad pcb) onto thebackplate and make sure that the tamper switch operates.7

Pagina 12 - User Control

9750 Hardwired Control Panel Installation and Programming Guide.© Cooper Security Limited. 2000Every effort has been made to ensure that the contents

Pagina 13 - 2. Technical Description

14 4964783. InstallationWiring the Control UnitCable EntriesThe control unit case back provides several cable entries. The back isdesigned to stand aw

Pagina 14 - Control Unit PCB and Case

496478 153. InstallationRemote KeypadsKeypad AddressingThe 9750 control unit is supplied with one remote keypad. If you have fittedmore keypads then e

Pagina 15 - 9755 Expander

16 4964783. InstallationConnecting KeypadsFigure 11 shows the connections for any of the remote keypads.Exit Terminate ButtonTo connect an exit termin

Pagina 16 - Compatible Equipment

496478 173. InstallationDetector Circuit ConnectionsThe left hand edge of the main PCB provides 14 connectors that can be usedfor up to 8 zones.Four W

Pagina 17 - 3. INSTALLATION

18 4964783. InstallationUsing Programmable OutputsOP1, 2 and 3 are "pull down type" outputs that provide negative appliedcontrol signals. Th

Pagina 18 - Fitting a 9930 LCD Keypad

496478 193. InstallationWiring KeyswitchesFigure 15 shows the connections for a 9928 Keyswitch Interface.Note: You can fit only one keyswitch interfac

Pagina 19 - 496478 13

20 4964783. InstallationInstalling a CommunicatorThe 9750 control unit contains a built in communicator on the main PCB. Inaddition the control unit

Pagina 20 - Mains Connection

496478 213. InstallationIf either of these functions detect a failure the system gives a programmableLine Fault Response (programming command 106).Sta

Pagina 21 - Remote Keypads

22 4964783. Installationagainst which approval was granted. Note the approval label on the mainPCB.RENThe Ringer Equivalence Number (REN) of the built

Pagina 22 - Sounders

496478 233. InstallationThe terminals on the 9750 control unit main pcb are described as SafetyExtra-Low Voltage circuits (SELV), according to the def

Pagina 23 - Connecting a 9755 Expander

496478 iContentsContents1. INTRODUCTION ... 1Operator Controls and

Pagina 24 - Using Programmable Outputs

24 4964783. InstallationCaution: The connection of only one such series apparatus is allowedto be connected between a main apparatus (e.g., telephone)

Pagina 25 - Wiring Keyswitches

496478 253. InstallationFigure 18. Fitting a Plug ByCommunicator4. Make any necessary connections from the communicator to the CommsWiring Harness. Fi

Pagina 26 - Installing a Communicator

26 4964783. InstallationIf the system has already been installed:7. Re-connect the battery.8. Fit the case lid (don't forget to attach the earth

Pagina 27 - Approval

496478 273. InstallationInitial Start UpBefore applying power to the control unit, ensure that any remote keypad(s)have been addressed, and expanders,

Pagina 28 - Safety Notice

28 4964783. Installation

Pagina 29 - Connecting the Telephone Line

4. Programming496478 294. ProgrammingEntering Programming Mode“3. Installation - Initial Power Up” describes how to enter programming modefor the firs

Pagina 30 - 24 496478

4. Programming30 496478To change: Key-in: Notes DefaultZone nn nn ab nn = zone number 01 to 16(Note: for zones 1 to 9 keya = Zone type, one of:in “01”

Pagina 31 - 496478 25

4. Programming496478 31To change: Key-in: Notes DefaultSystem Reset 33 0 Eng reset off Y1 Eng reset onPA Reset 34 0 PA cust reset Y1 PA eng resetFirst

Pagina 32 - Fitting a Battery

4. Programming32 496478To change: Key-in: Notes DefaultLevel A Exit Time 44 1 10 Seconds2 20 seconds Y3 30 seconds4 45 seconds5 60 seconds6 120 second

Pagina 33 - Initial Start Up

4. Programming496478 33To change: Key-in: Notes DefaultOutput 1 Type, one of 81 0 Bell Y1 EE follow2 Armed lamp3 Set latch4 Shock sensor reset5 Walk t

Pagina 34 - 28 496478

ii 496478Contents4. Programming ... 29Entering Programming Mode

Pagina 35 - 4. Programming

4. Programming34 496478To change: Key-in: Notes DefaultLoad defaults 98 1 Load defaultsLeave programming 99Communications ProgrammingCall mode 101 0

Pagina 36 - 30 496478

4. Programming496478 35To change: Key-in: Notes DefaultDownloader Tel No 1 118 Maximum 31 digitsDownloader Tel No 2 119 Maximum 31 digitsFast Format c

Pagina 37 - 496478 31

4. Programming36 496478Leaving Programming ModeWhen all programming has been completed:1. Key-in ‘99 Y’ at the keypadThe display shows: 99:Exit Eng ?

Pagina 38 - 32 496478

4. Programming496478 37Restoring All Factory Default ProgrammingIf you wish to restore all factory default options then:1. Enter programming mode (if

Pagina 39 - * See “5. Testing”

4. Programming38 496478alarms operate whether the system is set or unset andcannot be omitted, and will always trigger communica-tions if fitted.Norma

Pagina 40 - Communications Programming

4. Programming496478 39Chime (C) (Key in X1) When enabled by the user, the system givesa non-alarm warning tone when any zones programmedas ‘Chime’ ar

Pagina 41 - 496478 35

4. Programming40 496478adjust the sensitivity you must enter the complete com-mand, for example to change the sensitivity to 3 you mustkey in: X7 + 3

Pagina 42 - Re-entering Programming Mode

4. Programming496478 41Local Sounder Delay on Entry (Command 26)Use option 1 (default) to delay local sounders for silent communications whenan entry

Pagina 43 - Programming Reference

4. Programming42 496478PA Reset (Command 34)If you wish to make the system engineer reset after a PA alarm then useoption 1. For user reset use option

Pagina 44 - 38 496478

4. Programming496478 43system by pushing an exit terminate button connected to a keypad.Note that the exit time is infinite in this option.Option 2: F

Pagina 45 - 496478 39

496478 iiiContentsAccess Mode (Command 114) ...

Pagina 46 - RedCare Reset (Command 23)

4. Programming44 496478strates the volume of the tone when you enter the digit.CSID Code (Command 50)To allow the customer to use the ‘Remote Reset’ f

Pagina 47 - System Reset (Command 33)

4. Programming496478 45“Installer Mode”. The system sets its internal clock/calendar to the timeyou have given it.Abort Reset (Command 53)Option 0 ens

Pagina 48 - Alarm Abort (Command 36)

4. Programming46 496478Level B Exit Time (Command 65)This command sets the exit time for Level B. See “Programming Commands”for options.Output Program

Pagina 49 - 496478 43

4. Programming496478 47Ready Lamp (Key in 6) This output is active when the system is inDay, and if there are no faults. The output is inactivewhen th

Pagina 50 - CSID Code (Command 50)

4. Programming48 496478Load Full Defaults (Command 98)Use this command to load default values for all commands.1. Enter programming mode (if you are n

Pagina 51 - 496478 45

4. Programming496478 49then close down and dial the second telephone number andattempt to connect to the remote receiver. If received andacknowledged

Pagina 52 - 46 496478

4. Programming50 496478Entering a valid access code silences the sounders andthe displays indicates a telephone line fault. The systemcan be set again

Pagina 53 - 496478 47

4. Programming496478 51(which represents the “R” or Recall button on a tel-ephone) which is detected by the exchange as a requestfor a new clean line.

Pagina 54 - Call Mode (Command 101)

4. Programming52 496478Access Mode (Command 114)This function allows you to provide extra security when a remote PC isdialling into the system. Once t

Pagina 55 - Reporting Type (Command 103)

4. Programming496478 53The system can store telephone numbers up to 31 digits long.You can use the A key to insert a pause (four seconds).To enter a n

Pagina 57 - Rings to Answer (Command 112)

4. Programming54 496478Fast Format Channels (Command 121)If you selected Fast Format reporting type in command 103 then you can usecommand 121 to allo

Pagina 58 - 52 496478

4. Programming496478 55cisaByrammuSetaidemretnIIlluFeriFYYYYcinaPYYYYsseruDYYYYAPdapyeKYYYYralgruBYYYYtuoemittixEYYYYrepmatrosneSYYYYerotserrepmatrosn

Pagina 59 - 496478 53

4. Programming56 496478The system also provides a “custom” mode which allows any combination ofevent information. However, you must use <Downloader

Pagina 60 - Report Mode (Command 131)

496478 575. Testing5. TestingReading the Log (Command 90)The control unit keeps a 250 event log of recent events. Each event isrepresented by a two di

Pagina 61 - 496478 55

58 4964785. TestingUnn Znn OmitUnn Znn UnomitFire Znn AlarmFire Znn RstrFire Znn ResetPA Znn AlarmPA Znn RstrUnn System UnsetPA Knn AlarmBurg Znn Alar

Pagina 62 - 56 496478

496478 595. TestingEngineer Walk Test (Command 97)Allows the engineer to test all devices on the system.1. Enter programming mode.2. Key in 97 YThe di

Pagina 63 - 5. Testing

60 4964785. Testing

Pagina 64 - 58 496478

496478 61IndexIndexSymbols24 hour alarm ... 4724 hour zones ... 38AAccess

Pagina 65 - 496478 59

62 496478IndexDDefaults ... 30restoring ...

Pagina 66 - 60 496478

496478 63IndexPPA ... 5, 10PA reset ... 42Panic Alar

Pagina 67

496478 11. Introduction1. INTRODUCTIONThe 9750 is designed to be fully programmable to suit individual site require-ments and user needs.The system co

Pagina 68

64 496478Index

Pagina 69

Cooper Security LtdSecurity HouseXerox Business ParkMitcheldeanGloucestershireGL17 0SZProduct Support (UK) Tel: (09068) 616343Between 09:00 and 17:30

Pagina 70 - 64 496478

2 4964781. IntroductionBefore attempting to program the system, make sure you are completelyfamiliar with the functions of the system and its programm

Pagina 71

496478 31. IntroductionOperator Controls and Displays - 9930Figure 2. 9930 Remote Keypad.The 9930 keypad has a single line 16 character LCD display th