4. Programming
496478 37
Restoring All Factory Default Programming
If you wish to restore all factory default options then:
1. Enter programming mode (if you are not already there).
2. Key in 98 Y at the keypad.
The display shows: 98:Load Default
3. Press 1. (You can press X to stop the procedure if you change your
mind at this stage.)
4. Press Y.
The keypad gives a double confirmation tone and the system loads the
factory default command values, erasing all previously programmed
values.
Notes:The log is protected and cannot be erased by the Installer.
Programming Reference
Zone Programming (Commands 01 to 16)
The zone programming commands 01 to 16 take two or more numbers. The
first number describes the zone type, subsequent numbers describe the zone
attributes.
When you key in the zone number and press Y the display shows the zone
number and any text caption for the zone. (Note that the zone text can be
changed using <Downloader>, but not from the keypad.) Press Y again to
start entering the zone types and attributes. When you have entered the zone
type and attributes press Y once more to store the changes.
Zone Types
The following types are available:
Not Used (NU) The system ignores Zones with this type. Key in 0 for
zone that will not be used.
Note: If a zone is programmed as ‘Not Used’, it is not necessary to link the circuit or
anti-tamper connections.
Panic Alarm (PA) (Key in 1) Operating a device programmed as ‘Panic
Alarm’ will start either a silent alarm transmission to the
central station, or an audible alarm, depending on how
you have programmed PA Response, (see command 30).
PA alarms operate whether the system is set or unset,
and cannot be omitted.
Fire (FR) (Key in 2) Smoke or heat detectors connected to FR type
zones cause the speakers to give a distinctive fire signal
(internal sounders pulsing “Dee Dah Dee Dah...”). Fire
Commenti su questo manuale