4. Programming
54 496478
Fast Format Channels (Command 121)
If you selected Fast Format reporting type in command 103 then you can use
command 121 to allocate one of the following events to each of the 8 chan-
nels:
0 Not used 8 Detector Low Battery
1 Fire 9 Supervision Loss
2 PA X1 RF Jamming
3 Burglar X2 AC Fail
4 Open/Close X3 Tamper Alarm (Day tamper)
5 Alarm Abort X4 Open (see note 1)
6 Technical Alarm X5 Close (see note 1)
7 Alarm Confirmation X6 Zone Omitted (see note 2)
Notes:1. X4 Open and X5 Close provide the same functions as 4 Open/Close, but on
two separate channels.
2. X6 Zone omitted - the control unit sends this signal for five seconds when a
user omits a zone.
Report Restorals (Command 123)
This option is only available if you have selected Scancom Fast format (
C103
).
Restore off (0) The system does not communicate restorals.
Restore on (1) Enabled. The system will communicate restorals.
Country Defaults (Command 126)
Use this command to select the country and PTT defaults. Note that the
system will ask for confirmation and you must press 1 Y to end the com-
mand. Note that this command loads default access codes and programming
options. See “Programming Commands” for details of the options available.
Report Mode (Command 131)
SIA reports are called ‘Telegrams’. Each telegram contains the site identifica-
tion number (normally six digits long) and relevant event information. The
amount of information reported depends on the SIA mode you select: Basic,
Intermediate, or Full. Figure 23 shows the types of report for each mode. Use
the table to decide which mode is appropriate for the installation.
Option 0 = Basic
Option 1 = Summary
Option 2 = Intermediate
Option 3 = Full