4. Programming
42 496478
PA Reset (Command 34)
If you wish to make the system engineer reset after a PA alarm then use
option 1. For user reset use option 0.
First Circuit Response (Command 35)
If you select option 0 (Lock out) then the complete system rearms at the end
of the programmed bell run time, but excludes the first zone to activate during
the set cycle.
If you select option 1 (Re-arm) then, when an alarm occurs, the complete
system (including the first zone to activate) rearms at the end of the pro-
grammed bell run time (providing the zone is closed). While the zone is open,
the system locks it out. If the zone closes after the system rearms, the
system reinstates it.
Alarm Abort (Command 36)
Users occasionally trigger false alarms by accident. The 9750 can be pro-
grammed to allow users to abort an alarm by enabling option 1.
If a user accidentally triggers an alarm while the system is set, then the
control unit activates Channel 3, starts the bell delay timer and alarm abort
timer. To abort the alarm the user must enter a valid access code during the
abort period. When the user successfully enters the code during the abort
period the system deactivates Channel 3 and triggers the programmed abort
channel simultaneously in order to signal a separate code abort, as required
by some alarm receiving centres.
Note: The alarm abort period is controlled by the alarm receiving centre.
Daytime Tamper Communication (Command 37)
This command controls how the control unit reports tampers while the alarm
system is unset.
With option 1 selected the system communicates these types of tamper
event to the central station and starts the internal sounder.
With option 0 selected the system starts the internal sounder only.
Level A Exit Mode (Command 39)
Use this command to select one of the system’s three exit modes:
Option 0: Timed. Use this option EITHER if the user completes setting
the system by pushing an exit terminate button connected to a keypad
OR if no exit terminate button is connected, and the system sets after a
delay selected using Command 44.
Option 1: Terminate. Use this option if the user completes setting the