4. Programming
38 496478
alarms operate whether the system is set or unset and
cannot be omitted, and will always trigger communica-
tions if fitted.
Normal Alarm (NA) (Key in 3) A zone programmed as ‘Normal Alarm’ will
start an alarm when the system is set.
24 Hr Zone (24) (Key in 4) This zone causes an internal alarm if violated
when the system is unset, and a full alarm if the system is
set. Providing the Installer programs 24hr zones with
‘Omit Allow’, the user can omit 24 hour zones in Day
mode. Note that the control unit re-instates all 24Hr zones
if anyone sets the system.
Final Exit (FE) (Key in 5) Zones of this type must be the last detector to
be activated on exit, or the first to be activated on entry.
You can use zones of this type to finally set the system,
or to start the entry procedure. Use command 39 to set
the exit mode type.
Entry Route (ER) (Key in 6) Use this zone type for detectors sited between
the Final Exit door/detector and a keypad. If an ‘Entry
Route’ zone is violated when the system is set, an alarm
will occur. If the entry/exit timer is running when an Entry
Route zone is violated then no alarm occurs until the
entry/exit timer expires.
Shock
Analyser (SA) (Key in 7) You can apply this zone type to zones 1 to 4.
The system will not accept the attribute for zones 5 to 16.
(See also “Zone Attributes - Sensitivity”.)
Technical (TC) (Key in 8). Use this zone type when you want to monitor
equipment, for example a freezer, without raising a full
alarm.
If a technical alarm zone is activated while the system is
set, the system makes no audible alarm. However, when
a user unsets the system the keypad indicates a fault.
If a technical alarm zone is activated while the system is
unset then the system starts a pulsed tone from the
keypad. If programmed, the control unit also starts com-
munication. When a user enters a valid code the keypad
stops the tone and displays the zone.
Zone Attributes
Specific zone types can have one or more attributes programmed by the digit
after the zone command and type. (To remove an attribute, key in the at-
tribute digit again.)