4. Programming
496478 29
4. Programming
Entering Programming Mode
“3. Installation - Initial Power Up” describes how to enter programming mode
for the first time in a new installation. If you wish to enter programming mode
at any other time:
1. Make sure the system is unset.
2. Press 0, then key in the Engineer’s code (default 7890).
The display shows: Installer Mode
You are now in programming mode.
Note: While the system is in programming mode all keypads except the one you are
using will be locked, displaying “Busy”.
Programming Commands
When delivered from the factory the control unit already has default program
settings. To change the default programming you must be in programming
mode. Then:
1. Key in the appropriate command number and press Y.
The display shows the current value of the command.
2. Key in digits to select the value you require.
The display shows the new value.
3. Press Y to store the new value of the command.
If at any time you change your mind, repeat step 1 to 3. The table on the
following pages shows the commands and their options. ( A “Y” next to a
command value shows that it is the factory default.)
The factory default access codes are:
Engineer Code 7890
Access Code User 1 1234
Access Code 2 to 8 X 002 .... X 008 (inactive)
Duress Code X009 (inactive)
Notes:
1. The factory default Access Codes 02 to 08 and the Duress Code must be
changed by USER 1 to a four digit number to activate them. See “9750 User
Guide” for a more detailed explanation of changing user access codes.
2. To change the default zone descriptions use <Downloader>.