4. Programming
496478 41
Local Sounder Delay on Entry (Command 26)
Use option 1 (default) to delay local sounders for silent communications when
an entry alarm is triggered (required by some police forces). This option is
only valid if you have programmed a Bell Delay.
Use option 0 for no delay.
Exit Fault External Sounders (Command 27)
When programmed with option 0 of this command the system operates the
internal sounders if the user tries to exit while a zone is still violated (for
example a door is not shut). When option 1 is programmed the system
operates the external sounders as well as the internal sounders.
Status Display (Command 28)
Use option 0 of this command if you do not wish to show keypad displays
permanently. The keypad displays “Level Set” for 180 seconds after the user
sets the system and then reverts back to the time and date display. Use this
option when installing a system in the U.K.
When set to option 1 the keypad displays “Level Set” the whole time that the
alarm system is set.
Silent or Audible PA (Command 30)
This command selects how the system responds when a PA zone operates.
Option 0 (audible PA): the system operates the sounders and, if a
communicator is fitted, sends a PA message to the central station.The
keypad displays the PA zone when a user disarms the system.
Option 1 (Silent PA): The sounders stay silent. If a communicator is
fitted the system sends a PA message to the central station.The keypad
displays the PA zone when a user disarms the system.
System Reset (Command 33)
If you wish to make the system engineer reset, then use option 1. For user
reset use option 0.
Certain types of event will always need an Engineer reset, no matter what
option you choose for command 33. These events are:
Activating the tamper switch on the control unit, keypads, or expanders.
Auxilliary 12V supply fuse blown.
Remote expander failure caused by a remote keypad not responding
correctly.
Tamper return violation (usually from the external bell).
A low battery at the control unit.
Soak test fail indication.