5. Testing
Engineer Walk Test (Command 97)
Allows the engineer to test all devices on the system.
1. Enter programming mode.
2. Key in 97 Y
The display shows: 97: Walk Test
3. Open and close each alarm and tamper contact in turn.
The system gives a chime tone each time you open and close a detec-
tor contact. The displays shows: "A:Zone:" and the zone number of
every detector you have tested (note that the display displays each
zone number for one second, in sequence). If you also test the tampers
on each zone the display shows the letter "T" against each zone
number. .
4. Press X to stop the walk test.
Note that the Engineer's walk test allows you to test all zones including PA
zones, zone tampers, and control unit and bell tampers. The user's walk test
does not allow you to test PA, Fire, 24Hr, Technical zones, or tampers.