4. Programming
50 496478
Entering a valid access code silences the sounders and
the displays indicates a telephone line fault. The system
can be set again with the line fault present.
Note: Audible response is the NACOSS recommendation for line fault.
If the system is set then the control unit logs the event but
the keypads do not give any tone or display. The control
unit cancels any programmed bell delay if the line is out of
order when an alarm occurs.
Silent (2) If the system is unset then the keypad display indicates a
telephone line fault and the control unit logs the event.
The system may be set again with the line fault present.
If the system is set then the keypad does not give any
display or tone but the control unit does log the event. The
system cancels any programmed bell delay if the line is
out of order when an alarm occurs.
Line Integrity Checking (Command 107)
Integrity off (0) The control unit does not perform any line integrity
checks.
Integrity on (1) With this option enabled, the system seizes the telephone
line 12 hours after the last call and dials the first digit of
the first programmed telephone number. If the dial tone
disappears, then the line is good and the system hangs
up and resets the 12 hour timer. If the dial tone does not
disappear (the out of service tone is on the line), then the
system triggers the programmed Line Fail Response.
Dynamic Test (Command 108)
In dynamic testing the system makes a test call 24 hours after the last
communication. Select option 0 to disable dynamic test calls. Select option 1
to enable dynamic test calls.
Three Way Call - UK only (Command 109)
To use Three Way Call you must set the dialling type to DTMF (see com-
mand 102) and make sure that the BT Network Services Option of ‘Three
Way Calling’ is available on the telephone line to which the communicator is
connected.
Three way off (0) Disabled
Three way on (1) Three Way Call.
Operation: If the control unit triggers the communicator
and the communicator detects Off Hook or Incoming
Ringing, the communicator then sends a 80 ms trigger
Vedere la pagina 55