4. Programming
496478 39
Chime (C) (Key in X1) When enabled by the user, the system gives
a non-alarm warning tone when any zones programmed
as ‘Chime’ are opened. This facility operates only while
the system is in Day.
Notes:
1. ‘Chime’ is available only for Normal Alarm, Final Exit, Entry Route and Shock
Analyser zone types.
2. To make chime available from the keypad sounders but not the internal
sounder then program command 22 with option 0.
Soak Test (S) (Key in X2) Use this zone attribute if you want to place
under long term test a detector that you suspect is giving
false alarms. Zones with this attribute are disabled. If the
zone is opened while the system is set then the Service
LED glows and the control unit logs the event as a “Soak
Test Fail Zn” (n is the zone number) without sounding any
bells or starting signalling. The Service LED stays alight
until the Engineer resets the system.
Note: Soak test is available only for Normal Alarm, Entry Route and Shock Analyser
zone types.
Double
Knock (2) (Key in X3) Zones with this attribute will cause an alarm
condition only if the sensor generates two alarms events
within a five minute time window, or if the zone remains
open for more than 10 seconds. Programming a zone as
‘Double Knock’ is a way of reducing false alarms caused
by environmental changes, but is not normally recom-
mended.
Note: ‘Double Knock’ is available only for Normal Alarm and Entry Route zone types.
Omit Allow (O) (Key in X4) When applied to a zone, this attribute allows
the user to omit the zone.
Note: ‘Omit Allow’ is not available for Final Exit, PA and Fire zones.
Part Set B (b) (Key in X5) When applied, the zone will be armed when
the user selects Part Set B. Zones not selected will be
omitted.
Sensitivity (Key in X7) When you use this command you must also
enter an extra digit in the range 1 to 4 in order to set the
sensitivity of the shock sensor. 1 is least sensitive, 4 is
most sensitive. Note that to use this attribute you must
make one of zones 1 to 4 a shock analyser type. To