4. Programming
496478 47
Ready Lamp (Key in 6) This output is active when the system is in
Day, and if there are no faults. The output is inactive
when the system is full or part set, during any alarm, or
if a circuit fault prevents setting. Note that the output will
also be active when the control unit is in programming
mode.
24 Hour alarm (Key in 7) This output will become active if a zone
designated as ’24 Hours’ is violated. The output deacti-
vates when the system is disarmed.
Strobe (Key in 8) In an alarm the system operates the output.
The output remains active until the user disarms the
system.
Smoke Reset (Key in 9) This output is designed to be connected to
low voltage smoke detector reset terminals. The control
unit operates the output for 3 seconds when the system
is reset after any alarm has occurred.
Dual Ply Entry Warning (Command 86)
If users habitually exceed the entry time use option 1 to add a 30 second
extension during which the internal sounders give a warning tone. The
extension applies to both Full and Part setting. Note that if users exceed the
dual ply entry warning the system gives a full alarm.
Use Option 0 (default) to disable Dual Ply Entry.
Keypad Dual Key PA (Command 87)
This command allows users to raise a PA alarm by pressing keys 1 and 3
together on the keypad. Use option 1 to enable this facility, option 0 to dis-
able it. Note that this command also enables PA from keyswitches (See
“9928 Installation Guide”.)
Alarm Confirmation (Command 89)
Option 1 allows you to program the 9750 for Alarm Confirmation (verified
alarm), if required by your local Police Intruder Alarms Policy. When a detec-
tor causes an alarm the control unit activates Channel 3 (Burg). If a second
detector is triggered then the control unit activates the programmed alarm
confirmation channel.
Option 0 disables Alarm Confirmation.
Commands 90 - 97, See “5.Testing”