Pagina 1 - Instructions

MENVIERSECURITY M2000 Installation Instructions

Pagina 2 - Contents

10 M2000 Installation Instructions used, the digital communicator must be housed within the control panel, since the +12Vdc output is unfused. If req

Pagina 3 - Introduction

M2000 Installation Instructions 11 Relay Outputs ("8" in Figure 2.) The two relay outputs provide voltage-free changeover contacts, which c

Pagina 4 - Figure 2: Control Panel PCB

12 M2000 Installation Instructions Remote Reset Input ("12" in Figure 2.) For alarms that require an engineer or remote reset, the system c

Pagina 5

M2000 Installation Instructions 13 Menu. If you lock the NVM DO NOT forget the engineer passcode. Serial Printer Connector ("19" in Figure

Pagina 6 - Fitting and Wiring Procedure

14 M2000 Installation Instructions A serial or USB port cannot be used to connect a printer. 23PC(Female 9-pin)3255Ne two rker II(Female 9-pin)TxRx0V

Pagina 7 - Figure 5: Zone Wiring (FSL)

M2000 Installation Instructions 15 LEDs The LEDs (see Figure 2) have the following meanings: • LED1 (heartbeat) – Flashes once per second to indicat

Pagina 8 - Network 1 and 2 Connections

16 M2000 Installation Instructions Standards: EN 50131-1, PD 6662, TS 50131, BS4737, EN 50130. This equipment is compliant with EN 50136-2-1 &

Pagina 9 - Digital Communicator Outputs

2 M2000 Installation Instructions © Cooper Security Limited 2010 Every effort has been made to ensure that the contents of this book are correct. How

Pagina 10 - Re l a y

M2000 Installation Instructions 3 Introduction Figure 1 and Figure 2 show the layout of the control panel and the main features of the printed-circui

Pagina 11 - Communicator Line Fault

4 M2000 Installation Instructions 00V 0V 12V 12VCIRCUIT1Z1 T1CIRCUIT 2Z2 T2CIRCUIT 3Z3 T3CIRCUIT 4Z4 T4 Z5CIRCUIT 7CIRCUIT 5T5CIRCUIT 6Z6 T6 Z7 T7C

Pagina 12 - 2 x 16 Ohm Loudspeakers

M2000 Installation Instructions 5 Network 1Network 22000CONTROLPANEL5 Outputs8 Zones8 Outputs30 ID ZonesWiring Option 3MIDNode/IDNodeMaximum of 120 z

Pagina 13 - Engineer Keypad Connector

6 M2000 Installation Instructions Fitting and Wiring Procedure To install the control panel: 1. Remove the front cover by releasing its three retain

Pagina 14 - Power Availability

M2000 Installation Instructions 7 Zone Wiring ("1" in Figure 2.) The control panel has a set of eight on-board terminal blocks for the conn

Pagina 15 - Technical Specifications

8 M2000 Installation Instructions CIRCUIT 2Z2 T22K22K24K7TamperAla rmSh o rt C i r c u it Tamper AlarmOpen Circuit Tamper AlarmZo n e Re si st a n

Pagina 16 - BS4737, EN 50130

M2000 Installation Instructions 9 Figure 9. Fitting ADSL Filter ADSL01 Note: Make sure that you refit the jumpers to the pins shown in Figure 9 if y