4. Programming
46 496791
signal (internal sounders pulsing “Dee Dah Dee Dah...”).
Fire alarms operate whether the system is set or unset,
and will always trigger communications if fitted.
Normal Alarm (NA)(Key in 03) A zone programmed as ‘Normal Alarm’ will
start an alarm when the system is set.
24 Hr Zone (24) (Key in 04) This zone causes an internal alarm if violated
when the system is unset, and a full alarm if the system is
set. Providing the Installer programs 24hr zones with
‘Omit Allow’, the user can omit 24 hour zones in Day
mode. Note that the control unit re-instates all 24Hr zones
if anyone sets the system.
Final Exit (FE) (Key in 05) Zones of this type must be the last detector to
be activated on exit, or the first to be activated on entry.
You can use zones of this type to finally set the system,
or to start the entry procedure. Use Command 39 to set
the exit mode type.
Entry Route (ER) (Key in 06) Use this zone type for detectors sited between
the Final Exit door/detector and a keypad. If an ‘Entry
Route’ zone is violated when the system is set, an alarm
will occur. If the entry/exit timer is running when an Entry
Route zone is violated then no alarm occurs until the
entry/exit timer expires.
Shock
Analyser (SA) (Key in 07) You can apply this zone type to zones 1 to 4.
The system will not accept the attribute for zones 5 to 40.
(See also “Zone Attributes - Sensitivity”.)
Technical (TC) (Key in 08). Use this zone type when you want to monitor
equipment, for example a freezer, without raising a full
alarm. If a technical alarm zone is activated while the
system is set, the system makes no audible alarm.
However, when a user unsets the system the keypad
indicates a fault.If a technical alarm zone is activated
while the system is unset then the system starts a pulsed
tone from the keypad. If programmed, the control unit also
starts communication. When a user enters a valid code
the keypad stops the tone and displays the zone.
Key Box (KB) (Key in 09). This zone type is for use in Scandinavia only.
When a zone of this type is required, the Installer con-
nects the alarm wires of the zone to a special external
key box and the tamper wires to the box enclosure switch.
When someone opens the box the control unit logs the