4. Programming
56 496791
nal sounder. The system then operates the external sounder for the pro-
grammed Bell Duration. See “Programming Commands” for the Command
options.
Note: Command 41 has no effect if Alarm Confirmation (Command 89) is enabled
and either:
External Sounder (Command 162) is set to option 0, or
Internal Sounder (Command 161) is set to option 0. or
Alarm Response Mode (Commands 47, 63, 73 and 77) does not require
communications.
Bell Duration (Command 42)
This Command lets you set the length of time the system will operate the
external sounder during an alarm. See “Programming Commands” for the
Command options.
Level A Entry Time (Command 43)
This Command lets you set the Entry Time for Full Set or Partition A. See
“Programming Commands” for the Command options. The time starts when a
user opens any Final Exit zone.
Level A Exit Time (Command 44)
This Command lets you set the Exit Time for Full Set or Partition A. See
“Programming Commands” for the Command options.
Entry/Exit Tone Volume (Command 45)
In a single system use this Command to set the volume of entry/exit tones
from the internal sounder. If you select option 0 then the internal sounder
gives no entry/exit tones. If you select option 1 then the internal sounder
gives quiet entry/exit tones, while option 9 gives the loudest entry/exit tones.
The internal sounder demonstrates the volume of the tone when you enter
the digit. Note that this Command is not available in a partitioned system.
Tamper Alarm Annunciation (Command 46)
In a single system use this Command to chose which sounders the control
unit will activate for a tamper alarm while the system is unset.
Option 0 selects internal sounders only.
Option 1 selects keypad sounders only.
Option 2 selects internal sounders and keypad sounders.
This Command is not available in a partitioned system.
Partition A Alarm Response (Command 47)
If you have programmed the system for partitions then the following options
are available: