4. Programming
58 496791
Setting Time and Date (Command 51)
The system has an internal clock/calendar which it uses to date stamp the
log print-out. To set the system’s clock/calendar to the correct time and date:
1. Enter programming mode (if you are not already there).
2. Key in 51 at the keypad.
The display shows the current date, for example:
3. Key in two digits for the day number and press . Use a leading zero
for the first nine days of the month.
4. Key in the two digits for the month number and press . Use a leading
zero for January to September.
5. Key in the two digits of the year and press .
The display shows the current time, for example:
6. Key in two digits for the hours of the day and press . Use the 24-hour
clock.
7. Key in two digits for the minutes and press .
The keypad sounder gives a double “bleep” and the display shows
“Installer Mode”. The system sets its internal clock/calendar to the time
you have given it.
Omit Tamper Allowed (Command 52)
This Command ensures that the control unit omits the tamper contacts as
well as the alarm contacts when a user omits a zone. Note that you must give
the zone the omit attribute to allow the user to omit a zone.
Option 0 The control unit omits alarm contacts only
Option 1 The control unit omits both alarm and tamper contacts when the
user omits a zone.
Abort Reset (Command 53)
Option 0 Ensures that reset after abort is the same as system reset (see
Command 33).
Option 1 Enables customer reset after an abort.
BVVO Supervision (Command 54)
If the alarm system must meet BVVO radio supervision requirements then
select option 1. Once selected, the control unit will give a warning on the
keypad display when a user tries to set the system if a detector has lost
contact with the control unit for more than 15 minutes. If a detector loses
contact for more than two hours the control unit raises an alarm (see Com-
mand 128).