4. Programming
496791 61
Level B Alarm Response (Command 63)
Command 63 specifies the alarm response for part set B or Partition B. In a
single system:
Option 0 Internal sounders and keypad sounders.
Option 1 Internal sounders and keypad sounders
Option 2 Local alarm (internal and external sounder only).
Option 3 Full alarm (communication and internal/external sounders).
For a partitioned system:
Option 0 Keypad sounders only.
Option 1 Local alarm (internal and external sounder only).
Option 2 Full alarm (communication and internal/external sounders).
Level B Entry Time (Command 64)
This Command sets the entry time for part set B or Partition B. See “Pro-
gramming Commands” for options.
Level B Exit Time (Command 65)
This Command sets the exit time for Level B. See “Programming Com-
mands” for options.
Level C Final Exit Operation (Command 70)
Command 70 controls how the system will treat Final Exit zones in part set
Level C. (This Command does not affect Partition C in a Partitioned system.)
When the Command option is set to 0 any Final Exit zones included in part
set Level C will continue to act as Final Exit zones during part set Level C.
When the option is set to 1 any Final Exit zones included in part set Level C
will act as Normal Alarm zones during part set C.
Level C Entry Route Operation (Command 71)
Command 71 controls how the system treats Entry Route zones during part
set Level C. (This Command does not affect Partition C in a Partitioned
system.) When the option is set to 0 all Entry Route zones included in part
set Level C will continue to act as Entry Routes during part set Level C.
When the option is set to 1 any Entry Route zones included in part set Level
C will act as Final Exit zones during part set C.
Level C Exit Mode (Command 72)
Command 72 specifies the exit mode for part set C or Partition C. For a
single system the options are:
Option 0 The keypad sounders and any internal sounders give a low tone
when entering part set Level C. Use Command 75 to select the
exit time.