4. Programming
42 496791
To change: Key-in: Notes Default
CID Report Restorals 143 0 Mode Basic
1 Mode Basic + Restore Y
Plug by Comms Output 1 151 nn
Where nn is one of the following:
00 Not Used 13 Open
01 Fire (default) 14 Close
02 PA 15 Zone Omitted
03 Burglar 16 Medical
04 Open/Close 17 Key-Box
05 Alarm Abort 18 Anti-Mask
06 Technical Alarm 19 Smoke Detector
07 Alarm Confirmation 20 Comms Acknowledge
08 RF Low Battery 21 Battery Fault
09 RF Supervision Loss 22 Alarm Partition A
10 RF Jamming 23 Alarm Partition B
11 AC Fail 24 Alarm Partition C
12 Tamper Alarm 25 Alarm Partition D
Plug by Comms Output 2 152 Default 02 PA See Command 151
Plug by Comms Output 3 153 Default 03 Burglar See Command 151
Plug by Comms Output 4 154 Default 04 Open/Close See Command 151
Plug by Comms Output 5 155 Default 15 Zone OmittedSee Command 151
Plug by Comms Output 6 156 Default 05 Alarm Abort See Command 151
Plug by Comms Output 7 157 Default 07 Confirm See Command 151
Plug by Comms Output 8 158 Default 06 Technical See Command 151
Note: The following Commands are available if you select option 1 for Com-
mand 89.
Confirm Timer 160 nnn
nnn is a time in the range 001 to 999 minutes. Default 030 minutes.
Internal Sounder 161 0 Sounder on Unconfirmed Alarm Y
1 Sounder on Confirmed Alarm
External Sounder 162 0 Sounder on Unconfirmed Alarm Y
1 Sounder on Confirmed Alarm
Confirmation After Entry 163 0 Never Y
1 One Zone
2 Two zones
User Reset After 164 0 Disabled Y
Confirmed Alarm 1 Enabled