4. Programming
496791 41
To change: Key-in: Notes Default
Fast Format Channels 121 a b
For built in Communicator a is the channel number 1 to 8
b is one of the following:
00 Not Used 11 AC Fail
01 Fire (default Ch 1) 12 Tamper Alarm
02 PA (default Ch 2) 13 Open
03 Burglar (default Ch 3) 14 Close
04 Open/Close (default Ch 4) 15 Zone Omitted (default Ch 5)
05 Alarm Abort (default Ch 6) 16 Medical
06 Technical Alarm (default Ch 8) 17 Key-Box
07 Alarm Confirmation (dlt Ch 7) 18 Anti-Mask
08 RF Low Battery 19 Smoke Detector
09 RF Supervision Loss
10 Jamming
Comms Acknowledge 122 0 Off Y
1On
Note: Options are only available if Command 0 is set to option 1 (Ireland).
Restoral Reporting 123 0 Restore off Y
1 Restore on
Reverse Open/Closed 124 0 Disabled
1 Reverse codes
No Close if CCT Omitted 125 0 Disabled
1 No close sent if more than one cct omitted.
Language 126 nn
nn = Language, one of:
0 = English(Y) 3 = Portuguese 6 = German 9 = Danish
1 = Italian 4 = Dutch 7 = Norwegian
2 = Spanish 5 = French 8 = Swedish
Radio Zone Supervision 128 0 Full alarm (all sounders plus comms) Y
Fail Response 1 Internal, external and keypad sounder
2 Keypad sounders
3 Comms only
4 Inhibit set
Telecommand requires 129 0 Yes Y
Entry Door to Unset 1No
Extended Report Mode 131 0 Basic Y
1 Summary
2 Intermediate
3 Full
Send Tamper as Burglary 132 0 Off Y
1On
Commenti su questo manuale