Programming Commands Quick Reference 9651
Page 76 11772232
Command Key in:
62 Level B Exit Mode (page 50)
62yny
n =
0 Timed low tone on setting
Y
1 Instant (no exit tone)
2 Silent (double "beep" after exit time)
3 Sets exit mode the same as Level A
63 Level B Alarm Response (page 50)
63yny
n = 0 Keypad sounders only
1 Internal and keypad sounders
Y
2 Local (all sounders, no comms)
3 Full (all sounders and comms)
65 Level B Exit Time (page 51)
65yny
n = 1 10 seconds
2 20 seconds
Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
67 Forbikobler Approved (page 51)
67yny
n = 0 Frb=Non-Appr (not approved)
1 Frb=Approved (approved)
Y
68 Forbikobler Door Timer (page 51)
68yny
n = 0 2 seconds
1 3 seconds
2 4 seconds
3 5 seconds
Y
4 10 seconds
5 20 seconds
6 30 seconds
7 60 seconds
8 120 seconds
9 255 seconds
69 Forbikobler Door Locking (page 51)
69yny
n =
0 Lock Timed
Y
1 Lock Toggled
70 Level C Final Exit Operation
(page 52)
70yny
n =
0 C=FE = FE (Final Exit)
Y
1 C=FE = NA (Normal Alarm)
71 Level C Entry Route Operation
(page 52)
71yny
n =
0 C=ER = ER (Entry Route)
Y
1 C=ER = FE (Start entry timer)
72 Level C Exit Mode (page 52)
72yny
n =
0 Timed low tone on setting
Y
1 Instant (no exit tone)
2 Silent (double "beep" after exit time)
3 Sets exit mode the same as Level A
73 Level C Alarm Response (page 52)
73yny
n = 0 Keypad sounders only
1 Internal and keypad sounders
Y
2 Local (all sounders, no comms)
3 Full (all sounders and comms)
75 Level C Exit Time (page 53)
75yny
n = 1 10 seconds
2 20 seconds
Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
Command Key in:
76 Level D Exit Mode (page 53)
76yny
n =
0 Timed low tone on setting Y
1 Instant (no exit tone)
2 Silent (double "beep" after exit time)
3 Sets exit mode the same as Level A
77 Level D Alarm Response (page 53)
77yny
n = 0 Keypad sounders only
1 Internal and keypad sounders Y
2 Local (all sounders, no comms)
3 Full (all sounders and comms)
79 Level D Exit Time (page 53)
79yny
n = 1 10 seconds
2 20 seconds Y
3 30 seconds
4 45 seconds
5 60 seconds
6 120 seconds
80 Forbikobler Chime (page 54)
80yny
n = 0 Bell push does not operate
sounders
Y
1 Bell push operates sounders
81 Output 1 Type (page 54)
81ynny
nn = Where n is one of:
00 Bell Y
01 EE Follow
02 Armed Lamp
03 Set Latch
04 Shock Sensor Reset
05 Walk Test
06 Ready Lamp
07 24-hour Alarm
08 Strobe
09 Smoke Sensor Reset
10 French Siren Test
11 Strobe Set
12 Pulse Set 1
13 Pulse Unset 1
14 Not used
15 Set Complete
16 Unset Complete
26 Pulse Set 1
27 Pulse Set 2
28 Pulse Set 3
29 Pulse Set 4
30 Pulse Unset 1
31 Pulse Unset 2
32 Pulse Unset 3
33 Pulse Unset 4
34 Fire
35 PA
36 Set Fail
37 General Fault
38 All Fault
Vedere la pagina 79