3. Installation 9651
Page 26 11772232
Figure 21. Fitting a Plug-by Communicator
3. Make any necessary connections from the communicator to the
communication wiring harness. The default is a positive voltage when the
output is inactive but this can be inverted if required using Command
159.
4. Plug the Communication Wiring Harness onto the communications
connector on the main PCB.
5. Re-fit the PCB to the support pillars. Secure the PCB to the support
pillars with the screws provided (Figure 22). Make sure that the bottom
left corner of the PCB is seated on its support pillar.
Figure 22. Fitting Control Unit PCB