9651 Programming - Programming Commands
11772232 Page 43
31: Zone Tamper User/Engineer Reset
Use this command to ensure that the system complies with national
requirements for resetting zone tamper indications while the system is unset.
If you select option 0 (the default), the user can reset the system after a zone
tamper.
If you select option 1, the user can silence the alarm after a zone tamper but
an engineer must reset the system by entering the Engineer Code, or by
using a remote or anti-code reset (Commands 23 and 50).
Note: See Commands 37 and 38 for reporting and resetting system tampers
(for example, attempts to open control unit or keypad cases).
33: System User/Engineer Reset
To require an engineer reset, select option 1. To permit a user reset, select
option 0 (the default). Certain types of events always need an engineer reset,
irrespective of the option that you choose here:
° Auxiliary 12V supply fuse blown
° Keypad missing or failed
° A low battery at the control unit.
34: PA User/Engineer Reset
To require an engineer to reset the system after a PA, select option 1. To
permit a user to reset the system after a PA, select option 0 (the default).
35: First Circuit Lockout
If you select option 0 (Lockout), the first zone to activate during the set cycle
is ignored until the system is unset. This is the default.
If you select option 1 (Rearm), the whole system (including the first zone to
activate) rearms at the end of the programmed bell run time, provided that the
zone is closed. While the zone is open, the system locks it out. If the zone
closes after the system rearms, the system reinstates it.
36: Alarm Abort
Users occasionally trigger false alarms by accident. Select option 1 to permit
them to abort under these circumstances.
If a user accidentally triggers an alarm while the system is set, the control unit
transmits an intruder alarm and starts the Bell Delay and Alarm Abort timers.
To abort the alarm, the user must enter a valid access code during the abort
period. If the user enters a valid code within this time, the system transmits a
restore of the intruder alarm and simultaneously transmits an abort.
Select option 0 (the default) to prevent users from aborting alarms in this way.