9651
Page 74 11772232
Programming Commands Quick Reference
Command Key in:
0 Country PTT Defaults (page 35)
0y
ny
n = Country:
0 = UK Y
1 = Italy (I)
2 = Spain (EE)
3 = Portugal (P)
4 = Netherlands (NL)
5 = France (FR)
6 = Belgium (B)
7 = Germany (D)
8 = Switzerland (CH)
9 = Austria (A)
X1 = Ireland (IRL)
X2 = OEM 1
X3 = OEM 2
X4 = Finland (FI)
X5 = Norway (N)
X6 = Denmark (DK)
X7 = Sweden (S)
Note: Executing this command loads all
defaults for the selected country.
01–X40
Zone Programming (page 35)
nnyyab
nn = Zone number:
01 to 08
a = Zone type, one of:
00 = NU (Not Used)
01 = PA (Panic Alarm)
02 = FR (Fire)
03 = NA (Normal Alarm)
04 = 24 (24-hour)
05 = FE (Final Exit) see X7 below
06 = ER (Entry Route) see X7 below
07 = SA (Shock Analyser) see X7 below
08 = TC (Technical Alarm)
09 = KB (Keybox)
10 = SD (Smoke Detector)
11 = KM (Keyswitch Momentary)
12 = KF (Keyswitch Fixed)
13 = AM (Anti-Mask)
14 = FB (Forbikobler) see X7 below
15 = AC (AC Fail)
16 = LB (Low Battery)
17 = BF (Battery Fault)
18 = PF (Power Output Fault)
19 = FL (Fault)
Command Key in:
b = Zone attributes, any of:
X1 = C (Chime)
X2 = S (14-day Soak Test)
X3 = D (Double Knock)
X4 = O (Omit Allowed)
X7 = 1–6 or 1–4
For zone type 07, shock analyser
sensitivity: 1 (low) to 6 (high)
For zone types 05, 06 and 14,
entry timer number: 1 to 4 (see
Commands 201–4 on page 65)
A = a (armed in Level A)
B = b (armed in Level B)
C = c (armed in Level C)
D = d (armed in Level D)
Default zone types:
Z01=FE abcd 1
Z02=ER abcd 1
Z03-Z07=NA abcd
Z08=PA abcd
Example: To set Zone 07 as a Normal
Alarm, active in Level B and with Omit
Allowed. Key in:
07yy Zone Number
03 Normal Alarm
B Active in Level B
X4 Omit Allowed
y to store the value of the Command
20 Change Engineer Code (page 40)
20ynnnny
ggggy
nnnn = New Engineer Code (Code) 7890
21 Zone Configuration (page 40)
21yny
n =
0 Closed circuit tamper (CC+ComA/T)Y
1 Fully supervised loop (FSL 2K2/4K7)
22 Loudspeaker Chime (page 40)
22yny
n= Loudspeaker Chime volume
0 Off ( keypad only)
1 (minimum) to 9 (maximum)
5
23 Remote Reset Enable (page 41)
23yny
n =
0 Off Y
1 On
Note: Set Command 33 to Option 1 and
set a CSID code with Command 50.
25 Internal Sounder Delay and Duration
(page 41)
25yny
n =
0 LS Timed (follows external sounder) Y
1 LS Cont (continuous)
27 Exit Fault External Sounder (page 41)
27yny
n =
0 Internal Y
1 Local
28 Status Display (page 41)
28yny
n = 0 Status Continuous (always visible)
1 Status Timed (visible for 30s after an
event)
Y
29 Entry Alarm Delay Time (page 42)
29yny
n =
0 Delay Off Y