Programming - Programming Commands 9651
Page 58 11772232
If the system is unset, the control unit logs the event and the keypads
emit a short audible tone every minute. Entering a valid access code
silences the sounders and the keypad displays indicate a telephone
line fault. The system can be set again with the line fault present.
If the system is set, the control unit logs the event but the keypads do
not emit a tone or display a message. If the line is out of order when
an alarm occurs, the control unit cancels any programmed Bell Delay.
Note: Compliance with the NSI recommendation requires option 1.
2 Silent.
If the system is unset, the control unit logs the event and the keypad
displays indicate a telephone line fault (without giving any audible
warning). The system may be set again with the line fault present.
If the system is set, the control unit logs the event but the keypads do
not display a message. If the line is out of order when an alarm
occurs, the control unit cancels any programmed Bell Delay.
126: Select Language
The control unit can display messages on the keypads in several languages.
Select option for the language you wish to use:
0 English (default) 6 Deutsch (German)
1 Italian 7 Norsk (Norwegian)
2 Espanol (Spanish) 8 Svenska (Swedish)
3 Port (Portuguese) 9 Dansk (Danish)
4 Nederl (Dutch) X1 Suomi (Finnish)
5 Francai (French)
Note: This overrides the default language loaded when the Country is selected
with Command 0.
134: AC Fail User/Installer Reset
Use this command to determine how AC Fail alerts are reset.
Option
0 No Reset Required (default). An alert is generated when the mains
power supply fails and reset automatically when the supply is
restored.
1 User Reset. An alert is generated when the mains power supply fails
and can be reset by the user or installer when the supply is restored.