9651 Programming - System Configurations
11772232 Page 73
System Configuration
PD 6662 / prEN 50131-1: 2004 Compliance
EN 50131-1: 2004, Alarm systems – Intrusions and Hold-up Systems – Part 1:
System Requirements, requires that an alarm system does not display any
detailed information until a user enters a valid access code or presents a valid
proximity tag. The system should display an alert to inform users that there is
information to view. There are four grades of system:
Grade 2X
The 9651 control unit can be configured to comply with this grade.
Grade 2
9651 control units are not designed to comply with this grade.
Grade 3
9651 control units are not designed to comply with this grade.
Grade 4
9651 control units are not designed to comply with this grade.
Note: 9651 control units do not reflect variations set out in EN 50131-1:1997.
Programming for Compliance
Use the following setting to ensure compliance with PD 6662 / prEN 50131-1:
2004.
N/A = Not applicable
Command Grade 1/2 Page Notes
21 any 40
27 0 41
28 2 41
29 1 42
37 any 44
41 10 min 46
42 15 min 46
56 G1 – any
G2 – 1
49 Applies when using proximity tags because the
installer and master user still use access codes
63 2 50
73 2 52
77 2 53
134 1/2 58 Option 1 is recommended
135 1/2 59 Option 1 is recommended
137 59 Insurers may require a restriction
138 60 Insurers may require a restriction
139 60 Insurers may require a restriction
140 61 Insurers may require a restriction