3. Installation 9651
Page 24 11772232
The 9928 can be connected to either a momentary or a latched keyswitch
(see Figure 19). When using a momentary keyswitch, remove the jumper from
link M/C. When using a latched keyswitch, fit a jumper to link M/C.
Note:
If you connect a keyswitch through a keyswitch interface, it can be used
to set and unset the whole system or Level B only.