3. Installation 9651
Page 28 11772232
Initial Start Up
Before applying power to the control unit, ensure that:
All keypads have been addressed and connected.
All external and internal sounders are connected.
All wired zone circuits are connected.
Then:
1. Connect the battery to the control unit PCB.
2. Briefly short the Kick Start pins together (see Figure 3).
The internal sounder may sound. Ignore any display at this stage.
3. Key in the factory default User access code: 1234.
The internal sounder stops. Ignore any display or lamps.
4. Fit the case lid before applying mains power (this covers the live wiring
and closes the tamper switch).
5. Apply mains power.
6. Key in 0 followed by the factory default Engineer Code: 7890.
Note: You do not have to remove the case lid.
The display shows:
Installer Mode
You are now in installer (programming) mode.
The Programming Guide explains how to program the system.