Programming 9651
Page 32 11772232
Performing an Engineer Reset
To perform an engineer reset:
1. Check that the display is showing the alarm condition.
2. Enter installer mode.
3. Enter 99 yy.
The display returns to the time and date.
Restoring Default Command Settings
To restore all command options to their default (original) settings:
1. Enter installer mode.
2. Press 98y at the keypad.
The display shows:
Load Default
3. Press 1y at the keypad.
The keypad gives a double "beep" confirmation tone and the control unit
loads the default settings, erasing all previous selections.
Adding and Deleting Tags
You can use any industry-standard ISO tag or card with the 934 module. To
purchase tags from Cooper Security, quote part number Proxtagpk5.
A tag acts as an alternative to a user access code. You can assign a user a
tag, an access code, or both. You cannot assign a tag to the Master User
(User 01) or the Installer (User 00). This means you can assign up to 49 tags
on a system, one each for Users 2 to 50.
When presenting a proximity tag to a 9930 keypad, whether for programming
or for normal use, make sure that the tag is touching the front of the keypad to
the left of the display as shown in Figure 24. The 9940 keypad has a proximity
coil that makes the whole case sensitive to tags.