9651 Programming - Programming Commands
11772232 Page 41
23: Remote Reset Enable
Option 1 enables Remote Reset, which is designed to operate with the plug-
by communicator. After an alarm, the user keys in an access code to silence
the alarm but cannot reset the system. The first alarm message to display and
the Service lamp remain visible. The user contacts the Alarm Receiving
Centre (ARC), which verifies the user's identity and then sends a signal to the
control unit. The Service lamp goes out and the user can then reset the
system with any valid access code, provided that there are no faults.
Use option 0 (the default) to disable this function.
Notes:
1. To ensure option 1 works correctly, you must set System Reset to
Engineer (Command 33 option 1) and set a CSID code (Command 50).
2. To comply with PD 6662 / prEN 50131-1: 2004, the system must be set
to hide status information after 30 seconds (Command 28), in which case
the Service lamp will go out after the same period.
25: Internal Sounder Delay and Duration
Option 0 (the default) makes the internal sounder use the external Bell Delay
and Duration times. Option 1 makes the internal sounder continue after the
external Bell Delay expires, stopping only when a user enters an access code.
27: Exit Fault External Sounder
This command controls what happens when an exit timer completes and a
zone is still violated (for example, when a door is not shut).
Option
0 Internal (default). System operates the internal sounders only.
1 Local. System operates both internal and external sounders.
Note: Compliance with PD 6662 / prEN 50131-1: 2004 (see page 73) prohibits
an alarm after a failure to set the system, which would require
Command 27 to be set to option 0. However, if external sounders are
preferred, 9x5x control units also provide "Set Fail" outputs that can be
used to indicate that an alarm resulted from a set failure.
28: Status Display
If you select option 0 (the default), the keypad displays "Level Set"
continuously for the whole time that the alarm system is set. The keypad
lamps are illuminated if a relevant condition exists. Select option 1 to clear the
display and turn off the lamps 30 seconds after the user's last action.
The following table shows the effect of these settings in more detail.