Installer Mode Programming i-on40
Page 64
If you selected Fast Format in Report Type then you can
select Communications - ARC Reporting - Fast Format
Channels to allocate one of the following events to each of
eight channels (defaults in brackets):
Not used
Fire Alarm (default Channel 1)
Panic Alarm (default Channel 2)
Burglar Alarm (default Channel 3)
Open/Close (default Channel 4)
Alarm Abort (default Channel 6)
Technical Alarm (default Channel 8)
Confirmed Alarm (default Channel 7)
RF Low Battery
RF Supervision (see note 5)
RF Jamming (see note 5)
Mains Fail
Tamper
Open (see note 1)
Close (see note 1)
Zone Omitted - setting (Channel 5. see note 2)
Zone Omitted - system (see note 4)
Burg Partition 1 (partioned system only)
Burg Partition 2 (partioned system only)
Burg Partition 3 (partioned system only)
Burg Partition 4 (partioned system only)
Notes:1. Open and Close provide the same functions as
Open/Close, but on two separate channels.
2. Zone Omitted - the control unit sends this signal
for five seconds when a user omits a zone.
3. The control unit delays reporting/logging either
mains loss, or exiting Installer Menu with mains loss,
by 15-18 min (chosen randomly). For Scandinavia
the control unit waits at least 60 minutes before
reporting.
4. Appears only when DD243 options enabled.
5. The control unit communicates Jamming,
Supervision when the system is unset.