Installer Mode Programming i-on40
Page 38
Type: Active when: Assign to
Partitions?
External PSU
Fault (15)
An external power supply
fault signal triggers a
Power output fault zone.
The control unit deactivates
the output when the zone
has been restored and a
user has acknowledges the
fault by entering a valid
access code.
No
Tamper (16) The control unit detects
tamper on any device;
deactivates when tamper is
reset.
Yes
Zone Omit
(Setting) (17)
The user Omits a zone
while setting the system.
The output deactivates
when the control unit
restores the zone.
Yes
Zone Omit
(System) (18)
(Operates only when
DD243 is enabled.) In the
event of an unconfirmed
alarm, the system will
rearm itself when the
confirmation timer expires.
If the zone that caused the
unconfirmed alarm is still
active at the time of the
rearm, the control unit will
omit that zone and activate
the output. The control unit
will restore the zone and
output when a user or
engineer resets the
system.
Yes
General Fault
(19)
There is any event that
causes an alert indication
on the keypad.
Yes