i-on40 Installer Mode Programming
Page 55
enabled, or the communications outputs wired to an
appropriate communicator and correctly programmed).
This option controls the associated audible alarm.
Audible As well as starting communications the control
unit starts PA alarm tones from the keypads
and loudspeakers, and activates any siren
outputs.
Silent The control unit keeps the PA alarm silent:
there are no alarm tones from keypads or
loudspeakers and any siren outputs remain
inactive.
Displayed All keypads display a PA alert message
immediately (a user does not have to key in
their access code to see the message). The
control unit also starts PA alarm tones,
activates any siren outputs, and starts
communications.
Auto Rearm
(Appears when if System Options – DD243 – Confirmation is
set to “Off”, see page 51.)
To change the number of times that the system will re-
arm when the siren time expires select: System Options-
Auto Rearm.
Select NEVER to make the system never re-arm (the
system will go into alarm once only). Select one of the
other options to make the system re-arm once, twice,
three, four or five times, or always. The system re-arms
all closed zones, but not detectors that are still sending
alarm signals.
If the system has rearmed, then when a user enters the
system through the Final Exit door the control unit will
give an audible internal alarm in place of the normal
entry tone.
Siren Delay
When the system is set and (for example) an intruder
violates a zone, then the system waits for the