Installer Mode Programming i-on40
Page 34
type, and change its polarity. Programming plug-by
outputs is the same as programming wired outputs, but
you must use the Outputs – Plug-by Outputs menu.
Note: The activity of the plug-by outputs is affected by
the alarm response you select. For example, if you
select the alarm response “Siren” for Part Set B, then
the control units will not trigger the Plug-by-Outputs
if there is an alarm when the system is in part set B.
To make the plug-by outputs operate you must
select an alarm response that has communications.
Output Types
(Hint: You can select an output type quickly by keying
the number shown in brackets after the type’s name, for
example:“04” to select Open/Close, “02” to select Panic
Alarm, “19” to select General Fault. The number does not
appear on the keypad display.)
The output types available are:
Type: Active when: Assign to
Partitions?
Not Used (00) (Never)
Fire Alarm
(01)
The control unit starts a
fire alarm.
Yes
Panic Alarm
(02)
The control unit starts a
panic alarm.
Yes
Any of the following zones
are triggered:
Normal Alarm
Tamper (in a set system)
Entry Route
Tamper Zone (in a set
system)
Entry time expires
Burglar Alarm
(03)
24 hour (in a set system)
Yes
Vedere la pagina 37