Installer Mode Programming i-on40
Page 40
Type: Active when: Assign to
Partitions?
Entry Exit
Follow (23)
The entry or exit time
starts and deactivates at
the end of the entry/exit
time, or if the entry/exit
time is terminated. The
output can be used for a
separate entry/exit buzzer.
Note that the output does
not operate if the exit
mode is silent set or
instant set.
Yes
Armed (24) The system is full or part
set.
Yes
PIR Set Latch
(25)
The system is set. Inactive
when the system is unset
or an alarm condition
occurs. The output is active
for one second when a
reset is performed or when
the control unit leaves
installer mode.
Yes
Shock Sensor
Reset (26)
Exit time starts. The output
remains active for five
seconds. Use this output to
reset shock sensors (for
example, the "Viper").
Yes
Walk Test
(27)
A user starts Installer- or
User Walk Tests. Also
active during the time
between silencing and
resetting the system. This
output can be used on
movement detectors that
are able to switch off the
Walk Test lamp in any
state other than a Walk
Test.
No